    Mapping of Permeability Damage Around Perforation Tunnels

    Thumbnail
    View/Open
    JERTD2-26496#205_1.pdf (1.163Mb)
    Date
    2001
    Author
    C. Ozgen Karacan
    Abraham S. Grader
    Phillip M. Halleck
    Metadata
    Show full item record
    Abstract
    We have investigated porosity and permeability damage around perforations using a combination of transient analysis and X-ray CT. The method applied allowed us to perform the entire experiments on samples under simulated in-situ stress conditions and to map variations in permeability along the length of the core as well as with radial distance from the perforation. Berea (10.2-cm (4-in.) dia) cores saturated with low-viscosity silicone oil were perforated using conventional-shaped charges (6-g HMX) and API RP43 procedures by using 6.88-MPa (1000-psi) effective stress and 5.16-MPa (750-psi) and 2.61-MPa (350-psi) underbalance. Low-permeability Torrey Buff Sandstone was also perforated using 5.16-MPa (750-psi) underbalance. After sufficiently flowing the perforations, higher-viscosity silicone oil was injected. The movement of fluids was tracked using X-ray CT to measure the local velocity of the viscous fluid front at different locations along the perforation. Results of these tests were compared in terms of permeability and porosity damage. Quantitative analysis on Berea cores show, for the specific charge and test conditions used, that damage extends approximately 2 cm (0.78 in.) from the center of the perforation. Comparison of tests performed with 2.41-MPa (350-psi) and 5.16-MPa (750-psi) underbalance show a clear increase in permeability near the tunnel wall at the higher underbalance. A zone of somewhat-reduced permeability exists at approximately 1.7 cm from the perforation center in the latter case. Porosity profiles calculated show that porosity is almost uniform out from the tunnel and there is no compacted zone near the tunnel wall in liquid-saturated cores. However, there is a high-porosity zone from the tunnel wall out about 2 mm. This may be due to a region of circumferential partings and small cracks that lead to high porosity or due to the possible artifacts discussed in the paper. Qualitative results have also been obtained for a tight sandstone for which underbalance was insufficient to remove debris from the perforation tunnel. CT images reveal that the plugged tunnel acts as a conduit for fluid flow, showing that the plugging material has significantly higher permeability than the surrounding rock.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/125087
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV