dc.description.abstractThe fault-tolerant control scheme utilizes grouping of currents to reduce the required number of controller outputs. Reduced current distribution matrices can be calculated with the constraint conditions of the controller outputs and the necessary condition for linearization. Decoupling chokes are not required for the control scheme with grouped currents since fluxes are isolated in C-cores. By reducing controller outputs and removing decoupling chokes the fault-tolerant control scheme is more efficient and practical in terms of industrial applications.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Fault-Tolerant Control of Magnetic Bearings With Reduced Controller Outputs
dc.typeJournal Paper
dc.journal.volume123
dc.journal.issue2
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.1369356
dc.journal.fristpage219
dc.journal.lastpage224
dc.identifier.eissn1528-9028
dc.keywordsControl equipment
dc.keywordsPoles (Building)
dc.keywordsBearings
dc.keywordsCurrent
dc.keywordsMagnetic bearings
dc.keywordsFailure
dc.keywordsRotors
dc.keywordsFlux (Metallurgy) AND Force
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2001:;volume( 123 ):;issue: 002