    Abstract
    Preliminary feasibility studies based on breakeven refrigeration thermodynamics, have been conducted for candidate power conditioning components in a transportable radar power system (Donovan, B.D. et al., 1995 “Effects of Refrigeration in a Transportable Cryogenic Aerospace Application,” Proc. 30th IECEC, Vol. 1, pp. 473–478; Ramalingam, M. et al., 1996 “Systems Analysis for a Cryogenic Aerospace Terrestrial Radar Power System,” Proc. 31st IECEC, Vol. 1). The analysis based on breakeven refrigeration thermodynamics revealed that in the case of a general switching device such as a power MOSFET, it would be more beneficial to operate it at 150 to 220 K, using a Stirling cycle-based cryocooler. The overall system efficiency was jeopardized by way of large input power requirements to cool small heat loads at lower temperatures, while the performance of the device itself suffered at higher temperatures. The break-even refrigeration thermodynamic analysis was also applied to multilayer ceramic capacitors at cryogenic temperatures. It was found that in order to avoid a power penalty for cooling the capacitor to 77 K, the cryocooled equivalent series resistance (ESR) value would have to be a factor of 40 lower than that of a conventional capacitor ESR value if using a Gifford-McMahon (GM) cooling cycle. A factor of 12 better improvement in ESR is required for a yet-to-be-developed more efficient Stirling cycle. In this paper, this break-even thermodynamic analytical concept was then partially extended from the component level to the radar power system level. The entire power system was sized based on several combinations of cryocooled generators, power conditioning, and antenna equipment. The analysis revealed that even though the radar output could potentially be increased two-to threefold by the introduction of cryocooled technologies, the sizes of the coolers begin to negate these advantages. Several power systems were evaluated with reference to a common figure-of-merit to arrive at an optimum configuration. [S0195-0738(00)00803-7]
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/123604
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV