Show simple item record

dc.contributor.authorJ. P. Bons
dc.contributor.authorJ. L. Kerrebrock
dc.date.accessioned2017-05-09T00:01:09Z
dc.date.available2017-05-09T00:01:09Z
dc.date.copyrightOctober, 1999
dc.date.issued1999
dc.identifier.issn0889-504X
dc.identifier.otherJOTUEI-28671#651_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/122969
dc.description.abstractAn experimental investigation was conducted on the internal flowfield of a simulated smooth-wall turbine blade cooling passage. The square cross-sectioned passage was manufactured from quartz for optical accessibility. Velocity measurements were taken using Particle Image Velocimetry for both heated and non-heated cases. Thin film resistive heaters on all four exterior walls of the passage allowed heat to be added to the coolant flow without obstructing laser access. Under the same conditions, an infrared detector with associated optics collected wall temperature data for use in calculating local Nusselt number. The test section was operated with radial outward flow and at values of Reynolds number and Rotation number typical of a small turbine blade. The density ratio was 0.27. Velocity data for the non-heated case document the evolution of the Coriolis-induced double vortex. The vortex has the effect of disproportionately increasing the leading side boundary layer thickness. Also, the streamwise component of the Coriolis acceleration creates a considerably thinned side wall boundary layer. Additionally, these data reveal a highly unsteady, turbulent flowfield in the cooling passage. Velocity data for the heated case show a strongly distorted streamwise profile indicative of a buoyancy effect on the leading side. The Coriolis vortex is the mechanism for the accumulation of stagnant flow on the leading side of the passage. Heat transfer data show a maximum factor of two difference in the Nusselt number from trailing side to leading side. A first-order estimate of this heat transfer disparity based on the measured boundary layer edge velocity yields approximately the same factor of two. A momentum integral model was developed for data interpretation, which accounts for coriolis and buoyancy effects. Calculated streamwise profiles and secondary flows match the experimental data well. The model, the velocity data, and the heat transfer data combine to strongly suggest the presence of separated flow on the leading wall starting at about five hydraulic diameters from the channel inlet for the conditions studied.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.title1998 Heat Transfer Committee Best Paper Award: Complementary Velocity and Heat Transfer Measurements in a Rotating Cooling Passage With Smooth Walls
dc.typeJournal Paper
dc.journal.volume121
dc.journal.issue4
dc.journal.titleJournal of Turbomachinery
dc.identifier.doi10.1115/1.2836717
dc.journal.fristpage651
dc.journal.lastpage662
dc.identifier.eissn1528-8900
dc.keywordsHeat transfer
dc.keywordsCooling
dc.keywordsMeasurement
dc.keywordsFlow (Dynamics)
dc.keywordsBoundary layers
dc.keywordsVortices
dc.keywordsBuoyancy
dc.keywordsTurbine blades
dc.keywordsHeat
dc.keywordsQuartz
dc.keywordsThickness
dc.keywordsVelocity measurement
dc.keywordsWall temperature
dc.keywordsMechanisms
dc.keywordsSensors
dc.keywordsParticulate matter
dc.keywordsTurbulence
dc.keywordsReynolds number
dc.keywordsCoolants
dc.keywordsExterior walls
dc.keywordsOptics
dc.keywordsChannels (Hydraulic engineering)
dc.keywordsLasers
dc.keywordsDensity
dc.keywordsMomentum
dc.keywordsRotation AND Thin films
dc.treeJournal of Turbomachinery:;1999:;volume( 121 ):;issue: 004