Show simple item record

dc.contributor.authorH. J. Weigl
dc.contributor.authorM. M. Bright
dc.contributor.authorA. J. Strazisar
dc.contributor.authorJ. D. Paduano
dc.contributor.authorL. G. Fréchette
dc.contributor.authorA. H. Epstein
dc.contributor.authorE. M. Greitzer
dc.date.accessioned2017-05-08T23:58:04Z
dc.date.available2017-05-08T23:58:04Z
dc.date.copyrightOctober, 1998
dc.date.issued1998
dc.identifier.issn0889-504X
dc.identifier.otherJOTUEI-28667#625_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/121258
dc.description.abstractRotating stall and surge have been stabilized in a transonic single-stage axial compressor using active feedback control. The control strategy is to sense upstream wall static pressure patterns and feed back the signal to an annular array of twelve separately modulated air injectors. At tip relative Mach numbers of 1.0 and 1.5 the control achieved 11 and 3.5 percent reductions in stalling mass flow, respectively, with injection adding 3.6 percent of the design compressor mass flow. The aerodynamic effects of the injection have also been examined. At a tip Mach number, Mtip , of 1.0, the stall inception dynamics and effective active control strategies are similar to results for low-speed axial compressors. The range extension was achieved by individually damping the first and second spatial harmonics of the prestall perturbations using constant gain feedback. At a Mtip of 1.5 (design rotor speed), the prestall dynamics are different than at the lower speed. Both one-dimensional (surge) and two-dimensional (rotating stall) perturbations needed to be stabilized to increase the compressor operating range. At design speed, the instability was initiated by approximately ten rotor revolutions of rotating stall followed by classic surge cycles. In accord with the results from a compressible stall inception analysis, the zeroth, first, and second spatial harmonics each include more than one lightly damped mode, which can grow into the large amplitude instability. Forced response testing identified several modes traveling up to 150 percent of rotor speed for the first three spatial harmonics; simple constant gain control cannot damp all of these modes and thus cannot stabilize the compressor at this speed. A dynamic, model-based robust controller was therefore used to stabilize the multiple modes that comprise the first three harmonic perturbations in this transonic region of operation.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.title1997 Best Paper Award—Controls and Diagnostics Committee: Active Stabilization of Rotating Stall and Surge in a Transonic Single-Stage Axial Compressor
dc.typeJournal Paper
dc.journal.volume120
dc.journal.issue4
dc.journal.titleJournal of Turbomachinery
dc.identifier.doi10.1115/1.2841772
dc.journal.fristpage625
dc.journal.lastpage636
dc.identifier.eissn1528-8900
dc.keywordsCompressors
dc.keywordsSurges
dc.keywordsRotors
dc.keywordsDesign
dc.keywordsDynamics (Mechanics)
dc.keywordsFlow (Dynamics)
dc.keywordsMach number
dc.keywordsFeedback
dc.keywordsStall inception
dc.keywordsTravel
dc.keywordsSignals
dc.keywordsTesting
dc.keywordsCycles
dc.keywordsControl equipment
dc.keywordsPressure
dc.keywordsEjectors AND Damping
dc.treeJournal of Turbomachinery:;1998:;volume( 120 ):;issue: 004