dc.description.abstractGenerally, for the seismic analysis of nuclear power plant structures, requirement of coupling equipment is checked by applying USNRC decoupling criteria. This criteria is developed for the equipment connected to the structure at one location. In this paper, limitations of this criteria and modifications required for application to real life structures such as pressurized heavy water reactor building are discussed. In addition, the authors endeavor to present a decoupling model for multi-connected structure-equipment. The applicability of the model is demonstrated with pressurized heavy water reactor building internal structure and steam generator.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDecoupling Criteria for Multi-Connected Equipment
dc.typeJournal Paper
dc.journal.volume120
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.2841892
dc.journal.fristpage93
dc.journal.lastpage98
dc.identifier.eissn1528-8978
dc.keywordsBoilers
dc.keywordsSeismic analysis
dc.keywordsNuclear power stations AND Heavy water reactors
dc.treeJournal of Pressure Vessel Technology:;1998:;volume( 120 ):;issue: 001