Show simple item record

dc.contributor.authorJ. A. Stone
dc.date.accessioned2017-05-08T23:57:08Z
dc.date.available2017-05-08T23:57:08Z
dc.date.copyrightMarch, 1960
dc.date.issued1960
dc.identifier.issn0098-2202
dc.identifier.otherJFEGA4-27220#144_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/120723
dc.description.abstractExperiments were run on a poppet valve operating in hydraulic oil. The experimental values of the flow forces and discharge coefficients were about 25 per cent below the predicted theoretical values. Although there was some scatter in the values of discharge coefficients, there was good correlation for the flow forces. Flow forces are strongly influenced by the downstream configuration. The smaller the diameter of the downstream chamber, the higher the forces. A poppet configuration was designed and tested which virtually eliminated the flow forces.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDischarge Coefficients and Steady-State Flow Forces for Hydraulic Poppet Valves
dc.typeJournal Paper
dc.journal.volume82
dc.journal.issue1
dc.journal.titleJournal of Fluids Engineering
dc.identifier.doi10.1115/1.3662504
dc.journal.fristpage144
dc.journal.lastpage154
dc.identifier.eissn1528-901X
dc.keywordsForce
dc.keywordsFlow (Dynamics)
dc.keywordsValves
dc.keywordsDischarge coefficient
dc.keywordsSteady state AND Electromagnetic scattering
dc.treeJournal of Fluids Engineering:;1960:;volume( 082 ):;issue: 001
dc.contenttypeFulltext