Show simple item record

dc.contributor.authorK. A. Morris
dc.date.accessioned2017-05-08T23:56:09Z
dc.date.available2017-05-08T23:56:09Z
dc.date.copyrightJune, 1998
dc.date.issued1998
dc.identifier.issn0022-0434
dc.identifier.otherJDSMAA-26246#216_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/120191
dc.description.abstractNoise control in a one-dimensional duct is analyzed. This problem is of practical interest and is also simple enough that a complete theoretical analysis is possible. It is shown that the optimal controller leads to an unstable closed loop. The noise reduction level achievable with a stable closed loop is calculated for arbitrary choices of sensor and actuator locations. This enables the best placement of sensors and actuators to be determined. Also, the analysis indicates that a “spatial waterbed” effect exists in some configurations of active noise control: i.e., that noise levels are increased for points outside of the region over which the design is done.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleNoise Reduction in Ducts Achievable by Point Control
dc.typeJournal Paper
dc.journal.volume120
dc.journal.issue2
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.2802412
dc.journal.fristpage216
dc.journal.lastpage223
dc.identifier.eissn1528-9028
dc.keywordsNoise control
dc.keywordsDucts
dc.keywordsActuators
dc.keywordsDesign
dc.keywordsSensor placement
dc.keywordsTheoretical analysis
dc.keywordsSensors
dc.keywordsControl equipment AND Noise (Sound)
dc.treeJournal of Dynamic Systems, Measurement, and Control:;1998:;volume( 120 ):;issue: 002
dc.contenttypeFulltext