Show simple item record

dc.contributor.authorD. W. Nutter
dc.contributor.authorD. L. O’Neal
dc.date.accessioned2017-05-08T23:53:15Z
dc.date.available2017-05-08T23:53:15Z
dc.date.copyrightSeptember, 1997
dc.date.issued1997
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26472#193_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/118576
dc.description.abstractAn experimental investigation was conducted to study the flash boiling process and the influence of the exiting restriction (orifice) size on the mass flow during flash boiling of HCFC-22 in a glass pressure vessel. An apparatus was built and a combination of tests were run with three interchangeable exiting orifices (1.59, 3.18, and 5.56 mm diameters). The flashed vapor was vented from a 1110-mL vessel to a large “semi-infinite” tank initially set at 120 kPa. Calculations revealed that the refrigerant flow exiting the vessel was choked, depending on the orifice size. Smaller orifices were choked longer, had slower depressurization rates, and reduced mass flow rates. The depressurization rates were greater for tests large offices which enabled the liquid to become more highly superheated, up to 41°C for one test case, and ultimately vaporize more refrigerant.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Influence of Orifice Size on the Mass Flow During Flash Boiling of HCFC-22 From a Small Vessel
dc.typeJournal Paper
dc.journal.volume119
dc.journal.issue3
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2794989
dc.journal.fristpage193
dc.journal.lastpage199
dc.identifier.eissn1528-8994
dc.keywordsFlow (Dynamics)
dc.keywordsBoiling
dc.keywordsVessels
dc.keywordsOrifices
dc.keywordsRefrigerants
dc.keywordsSuperheating
dc.keywordsVapors
dc.keywordsGlass AND Pressure vessels
dc.treeJournal of Energy Resources Technology:;1997:;volume( 119 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record