Show simple item record

dc.contributor.authorS. Garimella
dc.date.accessioned2017-05-08T23:53:14Z
dc.date.available2017-05-08T23:53:14Z
dc.date.copyrightDecember, 1997
dc.date.issued1997
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26474#242_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/118563
dc.description.abstractThe present study investigates the improvement in the performance of an absorption heat pump for residential space-conditioning due to the use of the ground as the heat source in the heating mode and the heat sink in the cooling mode. A baseline air-coupled single-effect ammonia-water heat pump is first designed to deliver 10.55 kW (36,000 Btu/h) of cooling load at the ARI rating conditions. Particular attention is paid to incorporating many realistic details of an operating system such as fuel combustion efficiencies of the burner, nonequilibrium conditions, and moist air processes in the air-coupled heat exchangers. A range of parametric studies is also conducted to investigate the variation in performance of this system with ambient conditions in the heating and cooling modes. The same system is then analyzed in a ground-coupled configuration. The instantaneous COP for the ground-coupled system is compared with the COP of the air-coupled system as a function of the time of the year and the corresponding variations in ambient and ground temperatures using 30-yr average climate data for various locations from the National Weather Service. Improvements in COP of up to 20 percent over the air-coupled system values (cooling mode COP of 0.495 at 35°C (95°F) and heating mode COP of 1.20 at 8.33°C (47°F)) are demonstrated in diverse geographic locations with widely varying heating and cooling loads. These improvements indicate that an efficient ground-coupled heat pump could be developed for residential space-conditioning applications using simple thermodynamic cycles and existing technology for the heat and mass exchange components.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAbsorption Heat Pump Performance Improvement Through Ground Coupling
dc.typeJournal Paper
dc.journal.volume119
dc.journal.issue4
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2794997
dc.journal.fristpage242
dc.journal.lastpage249
dc.identifier.eissn1528-8994
dc.keywordsAbsorption
dc.keywordsHeat pumps
dc.keywordsCooling
dc.keywordsHeat
dc.keywordsStress
dc.keywordsHeating and cooling
dc.keywordsHeating
dc.keywordsLocations
dc.keywordsClimate
dc.keywordsHeat sinks
dc.keywordsWater
dc.keywordsThermodynamic cycles
dc.keywordsHeat exchangers
dc.keywordsTemperature
dc.keywordsCombustion AND Fuels
dc.treeJournal of Energy Resources Technology:;1997:;volume( 119 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record