Show simple item record

dc.contributor.authorP. Kolluri
dc.contributor.authorA. Kamal
dc.contributor.authorS. R. Gollahalli
dc.date.accessioned2017-05-08T23:49:57Z
dc.date.available2017-05-08T23:49:57Z
dc.date.copyrightMarch, 1996
dc.date.issued1996
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26463#58_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/116850
dc.description.abstractExperiments with an inshot burner used in residential natural gas furnaces are presented. The concentrations of NOx , NO, and CO in the combustion products of partially aerated natural gas flames were measured in a laboratory combustion chamber. When the conventional circular venturi inlet of the inshot burner was replaced by elliptic venturi inlets, an increase of up to 30 percent in the primary-air entrainment and a decrease of up to 20 percent in the NOx emission index were observed. Temperature field measurements in the flames were in conformity with the emission index measurements.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleApplication of Noncircular Primary-Air Inlet Geometries in the Inshot Burners of Residential Gas Furnaces
dc.typeJournal Paper
dc.journal.volume118
dc.journal.issue1
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2792694
dc.journal.fristpage58
dc.journal.lastpage64
dc.identifier.eissn1528-8994
dc.keywordsFurnaces
dc.treeJournal of Energy Resources Technology:;1996:;volume( 118 ):;issue: 001