Show simple item record

dc.contributor.authorS. Colin
dc.contributor.authorA. Bonnet
dc.contributor.authorR. Caen
dc.date.accessioned2017-05-08T23:49:44Z
dc.date.available2017-05-08T23:49:44Z
dc.date.copyrightJune, 1996
dc.date.issued1996
dc.identifier.issn0022-0434
dc.identifier.otherJDSMAA-26224#259_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/116708
dc.description.abstractIn order to optimize the devices which incorporate flapper-nozzle systems, the behavior of these systems must be completely modeled theoretically. However, the complexity of the flow between the nozzle and the flapper generally requires an empirical calibration of the discharge coefficients. In this article we will propose two types of flapper-nozzle designs which make completely theoretical determination of steady flow possible. This is required for device optimization. The second design makes it possible to obtain strictly linear behavior, which offers several advantages compared to classic devices. The results of experimental testing correspond closely to the theoretical predictions.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA New High Supply Pressure Pneumatic Flapper-Nozzle With Linear Behavior
dc.typeJournal Paper
dc.journal.volume118
dc.journal.issue2
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.2802312
dc.journal.fristpage259
dc.journal.lastpage266
dc.identifier.eissn1528-9028
dc.treeJournal of Dynamic Systems, Measurement, and Control:;1996:;volume( 118 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record