| dc.description.abstract | Upper bounds on transient response magnitudes for a SISO continuous-time repetitive control system are derived. Limiting the size of these transients is shown to be related to limiting the ∞-norm of a transfer function product of filters used in the repetitive controller. The decay rate of the transients is related to the peak of a function of frequency called the regeneration spectrum, which has previously been shown in the literature to be a measure of the relative stability of the system. Bounds derived here, although conservative, can be useful in the design of the repetitive controller, as illustrated by means of an example. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | Transient Response of Repetitive Control Systems | |
| dc.type | Journal Paper | |
| dc.journal.volume | 118 | |
| dc.journal.issue | 4 | |
| dc.journal.title | Journal of Dynamic Systems, Measurement, and Control | |
| dc.identifier.doi | 10.1115/1.2802360 | |
| dc.journal.fristpage | 795 | |
| dc.journal.lastpage | 797 | |
| dc.identifier.eissn | 1528-9028 | |
| dc.tree | Journal of Dynamic Systems, Measurement, and Control:;1996:;volume( 118 ):;issue: 004 | |
| dc.contenttype | Fulltext | |