Show simple item record

dc.contributor.authorS. S. Garimella
dc.contributor.authorK. Srinivasan
dc.date.accessioned2017-05-08T23:49:31Z
dc.date.available2017-05-08T23:49:31Z
dc.date.copyrightDecember, 1996
dc.date.issued1996
dc.identifier.issn0022-0434
dc.identifier.otherJDSMAA-26230#795_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/116616
dc.description.abstractUpper bounds on transient response magnitudes for a SISO continuous-time repetitive control system are derived. Limiting the size of these transients is shown to be related to limiting the ∞-norm of a transfer function product of filters used in the repetitive controller. The decay rate of the transients is related to the peak of a function of frequency called the regeneration spectrum, which has previously been shown in the literature to be a measure of the relative stability of the system. Bounds derived here, although conservative, can be useful in the design of the repetitive controller, as illustrated by means of an example.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTransient Response of Repetitive Control Systems
dc.typeJournal Paper
dc.journal.volume118
dc.journal.issue4
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.2802360
dc.journal.fristpage795
dc.journal.lastpage797
dc.identifier.eissn1528-9028
dc.treeJournal of Dynamic Systems, Measurement, and Control:;1996:;volume( 118 ):;issue: 004
dc.contenttypeFulltext