    Abstract
    The design-point dehumidification performance (i.e., at ARI conditions) of a rotary dehumidifier wheel depends on its rotational speed, the sorption properties of the desiccant, the heat and mass transfer characteristics of the matrix, and the size of the dehumidifier. However, the real operating conditions of a rotary dehumidifier can vary significantly from the design point, given the large variations in operating conditions (i.e., the outdoor, indoor, and regeneration temperatures and humidities) for various locations during different times of the year. This paper investigates the variability of the dehumidification performance of a rotary dehumidifier and its dependence on operating conditions. Also, the effect of the operating conditions on the optimum rotational speed of a rotary dehumidifier, where the performance of a rotary dehumidifier is optimized, is described.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/115235
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV