| dc.contributor.author | S. Stoltze | |
| dc.contributor.author | J. Mikkelsen | |
| dc.contributor.author | B. Lorentzen | |
| dc.contributor.author | P. M. Peterson | |
| dc.contributor.author | B. Qvale | |
| dc.date.accessioned | 2017-05-08T23:47:00Z | |
| dc.date.available | 2017-05-08T23:47:00Z | |
| dc.date.copyright | June, 1995 | |
| dc.date.issued | 1995 | |
| dc.identifier.issn | 0195-0738 | |
| dc.identifier.other | JERTD2-26460#142_1.pdf | |
| dc.identifier.uri | http://yetl.yabesh.ir/yetl/handle/yetl/115219 | |
| dc.description.abstract | The waste-heat recovery in batch processes has been studied using the pinch-point method. The aim of the work has been to investigate theoretical and practical approaches to the design of heat-exchanger networks, including heat storage, for waste-heat recovery in batch processes. The study is limited to the incorporation of energy-storage systems based on fixed-temperature variable-mass stores. The background for preferring this to the alternatives (variable-temperature fixed-mass and constant-mass constant-temperature (latent-heat) stores) is given. It is shown that the maximum energy-saving targets as calculated by the pinch-point method (t ime a verage m odel, TAM) can be achieved by locating energy stores at either end of each process stream. This theoretically large number of heat-storage tanks (twice the number of process streams) can be reduced to just a few tanks. A simple procedure for determining a number of heat-storage tanks sufficient to achieve the maximum energy-saving targets as calculated by the pinch-point method is described. This procedure relies on combinatorial considerations, and could therefore be labeled the “combinatorial method” for incorporation of heat storage in heat-exchanger networks. Qualitative arguments justifying the procedure are presented. For simple systems, waste-heat recovery systems with only three heat-storage temperatures (a hot storage, a cold storage, and a heat store at the pinch temperature) often can achieve the maximum energy-saving targets. Through case studies, six of which are presented, it is found that a theoretically large number of heat-storage tanks (twice the number of process streams) can be reduced to just a few tanks. The description of these six cases is intended to be sufficiently detailed to serve as benchmark cases for development of alternative methods. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | Waste-Heat Recovery in Batch Processs Using Heat Storage | |
| dc.type | Journal Paper | |
| dc.journal.volume | 117 | |
| dc.journal.issue | 2 | |
| dc.journal.title | Journal of Energy Resources Technology | |
| dc.identifier.doi | 10.1115/1.2835330 | |
| dc.journal.fristpage | 142 | |
| dc.journal.lastpage | 149 | |
| dc.identifier.eissn | 1528-8994 | |
| dc.keywords | Heat storage AND Waste heat | |
| dc.tree | Journal of Energy Resources Technology:;1995:;volume( 117 ):;issue: 002 | |
| dc.contenttype | Fulltext | |