dc.description.abstractFracture toughness testing was conducted on compact tension specimens cut from the Fast Flux Test Facility primary piping materials of 16-8-2 and 308 stainless steel welds aged at 427 and 482°C for 20,000 and 50,000 hr. The ductile fracture behavior of the materials was characterized at 205, 427, and 482°C using multiple and electric-potential single-specimen techniques. Electric-potential data were used to caculate crack extensions via an electric-potential calibration equation for the construction of J-R curves. Results demonstrate that the critical fracture-toughness values are in good agreement with those from the multiple-specimen method. Results showed that 20,000-hr aging caused more than 35 percent degradation in fracture resistance, and 50,000-hr aging resulted in a slight increase in Jc for 16-8-2 stainless steel welds. It was found that the fracture toughness levels of the primary piping after long-term aging were high and adequate at the aging temperatures and that fuel handling temperature, nonductile fracture was not expected to occur in these materials.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFracture Toughness of Aged Stainless Steel Primary Piping Welds Evaluated by Multiple and Single-Specimen Methods
dc.typeJournal Paper
dc.journal.volume115
dc.journal.issue2
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.2929516
dc.journal.fristpage201
dc.journal.lastpage206
dc.identifier.eissn1528-8978
dc.keywordsPipes
dc.keywordsFracture toughness
dc.keywordsStainless steel
dc.keywordsWelded joints
dc.keywordsElectric potential
dc.keywordsFracture (Process)
dc.keywordsTemperature
dc.keywordsTension
dc.keywordsTest facilities
dc.keywordsDuctile fracture
dc.keywordsFuels
dc.keywordsElectrical resistance
dc.keywordsConstruction
dc.keywordsTesting
dc.keywordsCalibration AND Equations
dc.treeJournal of Pressure Vessel Technology:;1993:;volume( 115 ):;issue: 002