dc.description.abstractA typical nuclear plant has between 60 and 115 safety-related check valves ranging from 2 to 30 in. The majority of these valves control water flow. Recent studies done by the Institute of Nuclear Power Operations (INPO), Electric Power Research Institute (EPRI) and the US Nuclear Regulatory Commission (NRC) found that many of these safety-related valves were not functioning properly. Typical problems found in these valves included disk flutter, backstop tapping, flow leakage, disk pin and hinge pin wear, or even missing disks. These findings led to INPO’s Significant Operating Experience Report (SOER, 1986), and finally, NRC generic letter 89-04, which requires that all safety-related check valves in a nuclear plant be regularly monitored. In response to this need, the industry has developed various diagnostic equipment to monitor and test check valves, using technologies ranging from acoustics and ultrasonics to magnetic—even radiography has been considered. Of these, systems that depend on a combination of acoustic and ultrasonic techniques (Au-Yang et al., 1991) are among the most promising for two reasons: these two technologies supplement each other, making diagnosis of the check valves much more certain than any single technology, and this approach can be made nonintrusive. The nonintrusive feature allows the check valves to be monitored and diagnosed without being disassembled or removed from the piping system. This paper shows that by carefully studying the acoustic and ultrasonic signatures acquired from a check valve, either individually or in combination, an individual with the proper training and experience in acoustic and ultrasonic signature analyses can deduce the structural integrity of the check valve with good confidence. Most of the conclusions are derived from controlled experiments in the laboratory where the diagnosis can be verified. Other conclusions were based on test data obtained in the field.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAcoustic and Ultrasonic Signals as Diagnostic Tools for Check Valves
dc.typeJournal Paper
dc.journal.volume115
dc.journal.issue2
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.2929507
dc.journal.fristpage135
dc.journal.lastpage141
dc.identifier.eissn1528-8978
dc.keywordsEquipment and tools
dc.keywordsValves
dc.keywordsAcoustics
dc.keywordsSignals
dc.keywordsSafety
dc.keywordsDisks
dc.keywordsFlow (Dynamics)
dc.keywordsNuclear power stations
dc.keywordsPatient diagnosis
dc.keywordsPiping systems
dc.keywordsHinges
dc.keywordsFlutter (Aerodynamics)
dc.keywordsWater
dc.keywordsLeakage
dc.keywordsWear
dc.keywordsElectricity (Physics)
dc.keywordsUltrasonics AND Nuclear power
dc.treeJournal of Pressure Vessel Technology:;1993:;volume( 115 ):;issue: 002