Show simple item record

dc.contributor.authorB. H. Kim
dc.contributor.authorG. P. Peterson
dc.contributor.authorK. D. Kihm
dc.date.accessioned2017-05-08T23:41:06Z
dc.date.available2017-05-08T23:41:06Z
dc.date.copyrightDecember, 1993
dc.date.issued1993
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26452#278_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/111811
dc.description.abstractAnalytical and experimental investigations were conducted to identify and better understand the parameters that govern the entrainment of liquid droplets in high-velocity gas streams flowing over capillary wicking structures. Using a flow visualization technique, two modes of entrainment were identified and described for high-velocity gas flows over an intermittently interrupted liquid surface. These two modes, roll-wave entrainment and stripping entrainment, were found to correspond to the lower and upper critical gas velocities, respectively. Measurements of the critical gas velocities and the droplet size distribution (Sauter mean diameter) of the entrained sprays were made as a function of the capillary pore size for three different mesh sizes and were compared with several analytical models developed in previous investigations. The flow visualization results indicate that the upper critical velocity is insensitive to variations in the capillary pumping rate provided the capillary pores are properly primed. The experimental results also indicate that the critical velocity for a given mesh is strongly influenced by the mesh dimensions, but that the previously developed criteria for estimating the critical velocity results in an underestimation of the upper critical velocity for all but very small pore sizes. Finally, to resolve this problem a new analytical model for predicting the critical velocity was developed and shown to be accurate for a wide range of capillary pore sizes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalytical and Experimental Investigation of Entrainment in Capillary Pumped Wicking Structures
dc.typeJournal Paper
dc.journal.volume115
dc.journal.issue4
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2906433
dc.journal.fristpage278
dc.journal.lastpage286
dc.identifier.eissn1528-8994
dc.keywordsStructures
dc.treeJournal of Energy Resources Technology:;1993:;volume( 115 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record