dc.description.abstractValves for use in oilfield applications have been tested in free convective water environments with hot internal flows. Two-dimensional finite element modeling was shown to give accurate reproduction of the test results. A dimensionless temperature differential ratio was shown to give accurate prediction of the internal temperature of any point within the valve. This dimensionless ratio permits results of testing in a single thermal environment to be extended to a wide range of possible temperature conditions.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTesting and Modeling of Oilfield Valves in Extreme Temperature Situations
dc.typeJournal Paper
dc.journal.volume114
dc.journal.issue2
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2905936
dc.journal.fristpage158
dc.journal.lastpage162
dc.identifier.eissn1528-8994
dc.keywordsModeling
dc.keywordsTesting
dc.keywordsValves
dc.keywordsTemperature
dc.keywordsOil fields
dc.keywordsInternal flow
dc.keywordsFinite element analysis AND Water
dc.treeJournal of Energy Resources Technology:;1992:;volume( 114 ):;issue: 002