| dc.contributor.author | W. L. Guice | |
| dc.contributor.author | L. G. Hoang | |
| dc.date.accessioned | 2017-05-08T23:38:13Z | |
| dc.date.available | 2017-05-08T23:38:13Z | |
| dc.date.copyright | June, 1992 | |
| dc.date.issued | 1992 | |
| dc.identifier.issn | 0195-0738 | |
| dc.identifier.other | JERTD2-26444#158_1.pdf | |
| dc.identifier.uri | http://yetl.yabesh.ir/yetl/handle/yetl/110142 | |
| dc.description.abstract | Valves for use in oilfield applications have been tested in free convective water environments with hot internal flows. Two-dimensional finite element modeling was shown to give accurate reproduction of the test results. A dimensionless temperature differential ratio was shown to give accurate prediction of the internal temperature of any point within the valve. This dimensionless ratio permits results of testing in a single thermal environment to be extended to a wide range of possible temperature conditions. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | Testing and Modeling of Oilfield Valves in Extreme Temperature Situations | |
| dc.type | Journal Paper | |
| dc.journal.volume | 114 | |
| dc.journal.issue | 2 | |
| dc.journal.title | Journal of Energy Resources Technology | |
| dc.identifier.doi | 10.1115/1.2905936 | |
| dc.journal.fristpage | 158 | |
| dc.journal.lastpage | 162 | |
| dc.identifier.eissn | 1528-8994 | |
| dc.keywords | Modeling | |
| dc.keywords | Testing | |
| dc.keywords | Valves | |
| dc.keywords | Temperature | |
| dc.keywords | Oil fields | |
| dc.keywords | Internal flow | |
| dc.keywords | Finite element analysis AND Water | |
| dc.tree | Journal of Energy Resources Technology:;1992:;volume( 114 ):;issue: 002 | |
| dc.contenttype | Fulltext | |