Show simple item record

dc.contributor.authorM. De Lucia
dc.contributor.authorG. Manfrida
dc.date.accessioned2017-05-08T23:32:31Z
dc.date.available2017-05-08T23:32:31Z
dc.date.copyrightJune, 1990
dc.date.issued1990
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26432#124_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/106840
dc.description.abstractAn exergy balance for an industrial glass furnace was constructed on the basis of measured thermodynamic variables. The experimental data were collected for different operating modes, especially in relation to oxygen enrichment. Losses were classified as belonging to one of three categories: 1) chemical reaction, 2) dissipation of heat (by radiation or sensible heat) to the environment, 3) heat transfer. Using this method, optimum conditions, with reference to oxygen enrichment of the combustion air, can be determined and the processes where the bulk of input exergy is destroyed can be identified. These results allow the designer to select modifications to furnace design and/or changes in operating modes that will be effective in enhancing plant efficiency. The last step is a thermoeconomic cost evaluation of the tested plant.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleBreakdown of the Exergy Balance in a Glass Furnace
dc.typeJournal Paper
dc.journal.volume112
dc.journal.issue2
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.2905718
dc.journal.fristpage124
dc.journal.lastpage129
dc.identifier.eissn1528-8994
dc.keywordsGlass furnaces
dc.keywordsExergy
dc.keywordsHeat
dc.keywordsIndustrial plants
dc.keywordsOxygen
dc.keywordsHeat transfer
dc.keywordsCombustion
dc.keywordsRadiation (Physics)
dc.keywordsDesign
dc.keywordsFurnaces AND Energy dissipation
dc.treeJournal of Energy Resources Technology:;1990:;volume( 112 ):;issue: 002