Show simple item record

dc.contributor.authorV. C. Ting
dc.contributor.authorJ. J. S. Shen
dc.date.accessioned2017-05-08T23:29:50Z
dc.date.available2017-05-08T23:29:50Z
dc.date.copyrightMarch, 1989
dc.date.issued1989
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26425#22_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/105321
dc.description.abstractThis paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6, 4, 2-in.) orifice meters conducted at the Chevron’s Sand Hills natural gas flow measurement facility in Crane, Texas. Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters. Data were obtained at beta ratios ranging from 0.12 to 0.74 at the nominal conditions of 4576 kPa and 27°C (650 psig and 80°F) with a 0.57 specific gravity processed, pipeline quality natural gas. A bank of critical flow nozzles was used as the flow rate proving device to calibrate the orifice meters. Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points. The uncertainty of the calibration system was analyzed according to The American National Standard (ANSI/ASME MFC-2M-A1983). The 10.16 and 5.08-cm (4 and 2-in.) orifice discharge coefficients agreed with the ANSI and ISO standards within the estimated uncertainty level. However, the 15.24-cm (6-in.) meter deviated up to − 2 percent at a beta ratio of 0.74. With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron’s high Reynolds number test data taken at a larger test facility in Venice, Louisiana. The test results also successfully demonstrated that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleField Calibration of Orifice Meters for Natural Gas Flow
dc.typeJournal Paper
dc.journal.volume111
dc.journal.issue1
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3231397
dc.journal.fristpage22
dc.journal.lastpage33
dc.identifier.eissn1528-8994
dc.keywordsFlow (Dynamics)
dc.keywordsCalibration
dc.keywordsNatural gas
dc.keywordsReynolds number
dc.keywordsSands
dc.keywordsDischarge coefficient
dc.keywordsNozzles
dc.keywordsUncertainty
dc.keywordsAmerican Petroleum Institute
dc.keywordsPipelines
dc.keywordsDensity
dc.keywordsEquations
dc.keywordsFlow measurement
dc.keywordsTest facilities
dc.keywordsWater
dc.keywordsCranes AND Engineering standards
dc.treeJournal of Energy Resources Technology:;1989:;volume( 111 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record