dc.description.abstractAn experimental study is reported of the effects of partial admission on the fluid elastic stability of a heat exchanger tube array. The array geometry was a parallel triangular configuration with a pitch ratio of 1.47. Tests were conducted in a wind tunnel with uniform flow over from 33 to 100 percent of single span tubes. In these experiments, the flow location was also varied from center-span to the end supports. Additionally, tests were conducted with uniform flow over one span of two and three-span tube arrays. These results are compared with theoretical predictions.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePartial Admission Effects on the Stability of a Heat Exchanger Tube Array
dc.typeJournal Paper
dc.journal.volume110
dc.journal.issue2
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3265586
dc.journal.fristpage194
dc.journal.lastpage198
dc.identifier.eissn1528-8978
dc.keywordsStability
dc.keywordsHeat exchangers
dc.keywordsFlow (Dynamics)
dc.keywordsFluids
dc.keywordsGeometry AND Wind tunnels
dc.treeJournal of Pressure Vessel Technology:;1988:;volume( 110 ):;issue: 002