Show simple item record

dc.contributor.authorMasao Sakane
dc.contributor.authorMasateru Ohnami
dc.date.accessioned2017-05-08T23:27:16Z
dc.date.available2017-05-08T23:27:16Z
dc.date.copyrightJuly, 1988
dc.date.issued1988
dc.identifier.issn0094-4289
dc.identifier.otherJEMTA8-26922#247_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/103964
dc.description.abstractThis paper assesses the accuracy of the crack initiation detection methods for type 304 SS circumferential notched specimens subjected to strain and stress controlled low cycle fatigue loads at 873 K in air. The methods examined were DC potential drop method (PDM) and the maximum stress criterion in the strain controlled test while they were DC potential drop method and the minimum notch opening displacement method (NOD) in the stress controlled test. The DC potential method and the minimum notch opening displacement method were proved to have a sufficient accuracy for the detection of crack initiation while the maximum stress criterion has less accuracy. The crack length detection based on DC potential drop method is also discussed.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleElectrical Potential Drop and Notch Opening Displacement Methods for Detecting High Temperature Low Cycle Fatigue Cracks of Circumferential Notched Specimens
dc.typeJournal Paper
dc.journal.volume110
dc.journal.issue3
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.3226044
dc.journal.fristpage247
dc.journal.lastpage252
dc.identifier.eissn1528-8889
dc.keywordsElectric potential
dc.keywordsDrops
dc.keywordsFracture (Materials)
dc.keywordsDisplacement
dc.keywordsLow cycle fatigue
dc.keywordsHigh temperature
dc.keywordsStress
dc.keywordsCrack detection AND Pulse width modulation
dc.treeJournal of Engineering Materials and Technology:;1988:;volume( 110 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record