dc.description.abstractFluid transients in a pipeline caused by valve operation can be minimized by operating the valve in an optimally prescribed manner, in a given time of closure (t c > 2L /a ). Dynamic programming is used to select the operation of the valve (i.e., set the valve-operating policy) over the time period t c so that the pressure rise at the valve (the objective function) is minimized. Constraints on the valve closure policy may also be specified, e.g., monotonic valve closure. Application of this method to a simple pipeline with a reservoir at one end and a valve at the other end shows that the pressure rise at the valve is lower than when the valve is closed linearly with time. The benefits of dynamic programming are shown to be greatest when the time of closure t c is small. The method has also been applied to valve opening, so that the pressure drop at the valve is a minimum.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleValve Stroking to Control Water Hammer Transients Using Dynamic Programming
dc.typeJournal Paper
dc.journal.volume109
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3264861
dc.journal.fristpage94
dc.journal.lastpage100
dc.identifier.eissn1528-8978
dc.keywordsWater hammer
dc.keywordsValves
dc.keywordsDynamic programming
dc.keywordsPipelines
dc.keywordsPressure
dc.keywordsReservoirs
dc.keywordsFluid transients AND Pressure drop
dc.treeJournal of Pressure Vessel Technology:;1987:;volume( 109 ):;issue: 001