dc.description.abstractInterest in the decoupling of such secondary systems as floor-mounted equipment centers on two decoupled models, the “cascading” model and the “lumped” model. A set of decoupling criteria is derived which addresses both models. The solution is based on the two-degree-of-freedom system. Error in predicted frequency given by each decoupled model is presented. Similar results for response error are derived based on broad-band input to the supporting system. The broad-band input would be applicable to subsystems supported by primary structures. Recommendations are made for extension of the problem to arbitrary multiple-degree-of-freedom systems. The findings of this study will provide the analyst with the information necessary to choose the best decoupled model and will indicate whether decoupling should be attempted.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDecoupling of Secondary Systems for Seismic Analysis
dc.typeJournal Paper
dc.journal.volume108
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3264755
dc.journal.fristpage78
dc.journal.lastpage85
dc.identifier.eissn1528-8978
dc.keywordsSeismic analysis AND Errors
dc.treeJournal of Pressure Vessel Technology:;1986:;volume( 108 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record