Show simple item record

dc.contributor.authorE. I. Umez-Eronini
dc.contributor.authorJ. N. Cannon
dc.date.accessioned2017-05-08T23:22:18Z
dc.date.available2017-05-08T23:22:18Z
dc.date.copyrightJune, 1986
dc.date.issued1986
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26411#179_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/101048
dc.description.abstractA cold test model study of the staged cascade fluidized bed coal combustion process is described. Proper cascade flow of solids through the system was found to be sensitive to bed and downcomer distributor plate pressure drops. Control of bed depth by weir level was also complicated at high fluidization velocities by the process of entrained particles falling back into the downcomer. Bed to tube heat transfer coefficients ranging from 142 to 256W/m2 •K were measured at the top surface of a simulated boiler tube in shallow beds, 0.15 to 0.23m deep.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleNonradiative Heat Transfer Coefficients and “Cold” Operating Experience With a Laboratory SCFBC Model
dc.typeJournal Paper
dc.journal.volume108
dc.journal.issue2
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3231259
dc.journal.fristpage179
dc.journal.lastpage182
dc.identifier.eissn1528-8994
dc.keywordsHeat transfer coefficients
dc.keywordsFlow (Dynamics)
dc.keywordsCombustion
dc.keywordsSolids
dc.keywordsParticulate matter
dc.keywordsFluidization
dc.keywordsCascades (Fluid dynamics)
dc.keywordsCoal
dc.keywordsFluidized beds
dc.keywordsPressure drop AND Boiler tubes
dc.treeJournal of Energy Resources Technology:;1986:;volume( 108 ):;issue: 002