dc.description.abstractExperiments were performed to study the two-dimensional natural convection heat transfer from two heated isothermal horizontal cylinders to an isothermal-cooled rectangular enclosure. The experiments were designed to simulate the heat transfer encountered in underground heat distribution systems where steam and condensate lines are routed through underground or in-ground corridors (utilidors) from a central plant. The steam supply and condensate return lines were simulated with two copper cylinders. The fluid between the cylinders and enclosure was distilled water to simulate the Rayleigh number range encountered with air in actual utilidors. Results were obtained for the overall heat transfer coefficient between the two cylinders and the enclosure. The data was correlated over a Rayleigh number, RaL , range of 2.1 × 108 to 4.8 × 109 representative of the Rayleigh number, based upon a hypothetical gap width, in a typical utilidor exposed to extreme enclosure to piping temperature differential boundary conditions. The corresponding Nusselt numbers, NuL , ranged from 21 to 59 when both cylinders were heated for water as the intermediate fluid. Corresponding heat transfer coefficients calculated for the utilidor case with air as the intermediate fluid were found to be smaller compared to some other correlations for concentric cylinders.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental Free Convection From Piping in District Heating Utilidors
dc.typeJournal Paper
dc.journal.volume108
dc.journal.issue2
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3231258
dc.journal.fristpage173
dc.journal.lastpage178
dc.identifier.eissn1528-8994
dc.keywordsCentral heating
dc.keywordsNatural convection
dc.keywordsPipes
dc.keywordsCylinders
dc.keywordsRayleigh number
dc.keywordsFluids
dc.keywordsHeat transfer
dc.keywordsCondensed matter
dc.keywordsSteam
dc.keywordsWater
dc.keywordsHeat transfer coefficients
dc.keywordsIndustrial plants
dc.keywordsBoundary-value problems
dc.keywordsCopper
dc.keywordsHeat AND Temperature
dc.treeJournal of Energy Resources Technology:;1986:;volume( 108 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record