Show simple item record

contributor authorTarun R. Naik
contributor authorShiw S. Singh
contributor authorMohammad M. Hossain
date accessioned2017-05-08T22:41:57Z
date available2017-05-08T22:41:57Z
date copyrightApril 1996
date issued1996
identifier other%28asce%290733-9402%281996%29122%3A1%2821%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/86930
description abstractCoal-burning powerplants generate about 72,000,000 t (80,000,000 ton) of combustion by-products per year in the United States. Each tonne (1.1 ton) of by-products used in lieu of portland cement in concrete saves about 7,600,000 kJ (7,150,000 Btu) of energy, and prevents 1 t (1.1 ton) of CO
publisherAmerican Society of Civil Engineers
titlePermeability of High-Strength Concrete Containing Low Cement Factor
typeJournal Paper
journal volume122
journal issue1
journal titleJournal of Energy Engineering
identifier doi10.1061/(ASCE)0733-9402(1996)122:1(21)
treeJournal of Energy Engineering:;1996:;Volume ( 122 ):;issue: 001
contenttypeFulltext