Show simple item record

contributor authorJ. Geoffrey Chase
contributor authorMark Yim
date accessioned2017-05-08T22:39:03Z
date available2017-05-08T22:39:03Z
date copyrightSeptember 1999
date issued1999
identifier other%28asce%290733-9399%281999%29125%3A9%28987%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/85072
description abstractLinear buckling of column structures is an important design constraint in many structures, particularly where weight is a primary concern. Active strengthening is the application of feedback control to increase the critical buckling load of the structure. An important feature of this control problem is that the structure is inherently unstable when the axial load surpasses the critical buckling load. This research presents a design method for creating optimal buckling control systems using state or static output feedback. The primary feature of this method is the ability to select the designed closed loop, actively strengthened, critical buckling load. The stability of the resulting controllers is determined using Lyapunov methods. Simulation and experimental demonstration of this algorithm is performed using a column employing piezoelectric actuators, and MEMS-based strain sensors. The optimal buckling controllers developed are able to increase the critical buckling load by a factor of 2.9. The closed loop system is able to support lower axial loads indefinitely (>30 min).
publisherAmerican Society of Civil Engineers
titleOptimal Stabilization of Column Buckling
typeJournal Paper
journal volume125
journal issue9
journal titleJournal of Engineering Mechanics
identifier doi10.1061/(ASCE)0733-9399(1999)125:9(987)
treeJournal of Engineering Mechanics:;1999:;Volume ( 125 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record