description abstractAn experimental study is conducted to investigate the heat transfer and the pressure drop properties of a single-phase flow in a bayonet tube heat exchanger. A bayonet tube heat exchanger has only one circulating fluid, i.e., tap water. The circulating fluid is supplied at an ambient temperature (cold medium) and, as a result, it will be heated by an electrical heater (heat source). The bayonet tube heat exchanger is a two-pass heat exchanger. Different experiments were performed to show the relationships and the effects of different parameters such as the Reynolds number, friction factor, Nusselt number, overall heat transfer coefficient, and effectiveness on the purposed heat exchanger. To enhance the heat transfer rates, a helical tape is installed in the annulus between the inner and outer tube. The flow is considered as turbulent in both the plain tube and the helical tape. The recorded Nusselt number for heat exchanger with the helical tape is about 35.6% higher than that without helical tape. In addition, the helical tape increased the effectiveness by approximately 30.2%.
publisherAmerican Society of Civil Engineers
titleExperimental Study of the New Bayonet Heat Exchanger
typeJournal Paper
journal volume142
journal issue1
journal titleJournal of Energy Engineering
identifier doi10.1061/(ASCE)EY.1943-7897.0000281
treeJournal of Energy Engineering:;2016:;Volume ( 142 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record