Show simple item record

contributor authorX. H. Dai
contributor authorD. Lam
contributor authorE. Saveri
date accessioned2017-05-08T22:29:10Z
date available2017-05-08T22:29:10Z
date copyrightNovember 2015
date issued2015
identifier other46484900.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/81389
description abstractIn this paper, a group of demountable shear connectors have been developed and tested to assess their potential and suitability in terms of replacing welded shear studs. The experiments showed that these demountable shear connectors can be easily demounted after testing and have similar capacity and behavior to those of welded shear connectors. After the numerical simulation method had been validated against experimental observation, a parametric study was carried out to understand the effect of concrete grades and stud collar sizes on the shear resistance of demountable shear connections. Simple design calculation methods for welded shear connections or anchoring connections provided in European and American standards were checked to the suitability for assessment of this headed demountable shear connector.
publisherAmerican Society of Civil Engineers
titleEffect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors
typeJournal Paper
journal volume141
journal issue11
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0001267
treeJournal of Structural Engineering:;2015:;Volume ( 141 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record