description abstractSiloxanes, impurities in the biogas produced from anaerobic digestion of wastewater sludges, are transformed to silica dioxide sand during combustion of the biogas, which damages the heat exchanger and engine. Decamethylcyclopenta-siloxane (D5) and octamethylcyclotetra-siloxane (D4) were added to return activated sludge (RAS) and treated using a pulsed-electric field method [focused pulsed (FP)] that makes the sludge solids more readily converted to methane. With an FP treatment intensity (
publisherAmerican Society of Civil Engineers
titleUsing Focused Pulsed Technology to Remove Siloxane from Municipal Sewage Sludge
typeJournal Paper
journal volume142
journal issue1
journal titleJournal of Environmental Engineering
identifier doi10.1061/(ASCE)EE.1943-7870.0000975
treeJournal of Environmental Engineering:;2016:;Volume ( 142 ):;issue: 001
contenttypeFulltext