| description abstract | Electrical conductivity (EC) is used for monitoring different types of aqueous systems. The measured EC value at any temperature needs to be corrected for a standard temperature, for reporting or comparison, since EC is dependent on temperature. A temperature compensation factor has been derived for conductivity correction from anaerobic digester supernatant/centrate samples of five different wastewater treatment plants in western Canada. For a temperature compensation factor of | |