Show simple item record

contributor authorHenin
contributor authorMorcous
contributor authorM. K.
contributor authorTadros
date accessioned2017-05-08T21:58:46Z
date available2017-05-08T21:58:46Z
date copyrightAugust 2014
date issued2014
identifier other%28asce%29st%2E1943-541x%2E0000050.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/67893
description abstractPrecast concrete floor systems represent a major component of the cost and weight of precast concrete buildings. Hollow-core (HC) planking is considered the most common precast concrete floor system for residential and commercial buildings because of their economy, light weight, structural capacity, and ease of production and erection. However, the high thermal conductivity of HC planks hinders their use in radiant heated floor and roof applications where thermal insulation is needed. This paper presents the development of a precast/prestressed concrete sandwich floor panel that consists of an internal wythe of insulation and two external wythes of concrete similar to those used in sandwich wall panels. The main difference between the sandwich floor and wall panels is the design of shear connectors between concrete wythes to achieve full composite action under ultimate loads while simultaneously having an adequate creep resistance under sustained loads and acceptable deflection under live loads. Truss-shaped glass fiber-reinforced polymer ties, known as NU ties, were used as shear connectors because of their structural and thermal efficiency. The proposed floor panels have comparable weight and capacity to HC planks while being more thermally efficient and can easily be fabricated in standard casting beds with typical equipment, thus eliminating the high initial investment required for HC production. This paper presents the design, detailing, production, and testing of three 7.9-m-long (26-ft-long), 1.22-m-wide (4-ft-wide), and 200-mm-thick (8-in.-thick) specimens with 50-mm-thick (2-in.-thick) composite topping. The three specimens represent two different panel designs. One specimen has solid concrete ends and was designed for a total superimposed service load of 9.6 kPa (200 psf), whereas two specimens are fully insulated and designed for a total superimposed service load of 4.8 kPa (100 psf). The performance of the three specimens under flexure and shear loadings indicated that the proposed sandwich floor panels can achieve full composite action and have satisfactory structural performance and acceptable deflection characteristics.
publisherAmerican Society of Civil Engineers
titlePrecast/Prestressed Concrete Sandwich Panels for Thermally Efficient Floor/Roof Applications
typeJournal Paper
journal volume19
journal issue3
journal titlePractice Periodical on Structural Design and Construction
identifier doi10.1061/(ASCE)SC.1943-5576.0000213
treePractice Periodical on Structural Design and Construction:;2014:;Volume ( 019 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record