Show simple item record

contributor authorDominic L. Boccelli
contributor authorMitchell J. Small
contributor authorUrmila M. Diwekar
date accessioned2017-05-08T21:56:24Z
date available2017-05-08T21:56:24Z
date copyrightMarch 2007
date issued2007
identifier other%28asce%290733-9372%282007%29133%3A3%28303%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/67164
description abstractBoth inherent natural variability and model parameter uncertainty must be considered in the development of robust and reliable designs for drinking water treatment. This study presents an optimization framework for investigating the effects of five variable influent parameters and three uncertain model parameters on the least-cost treatment plant configuration (contact, direct, or nonsweep conventional filtration) that reliably satisfies an effluent particulate matter concentration constraint. Incorporating variability and uncertainty within the decision-making framework generates information for investigating: (1) impacts on total cost and treatment reliability; (2) shifts on the least-cost treatment configuration for providing reliable treatment; and (3) the importance of the individual variable and uncertain parameter distributions for reliably satisfying an effluent water quality constraint. Increasing the magnitude of influent variability and model parameter uncertainty results in a greater expected design cost due, generally, to increases in process sizing required to reliably satisfy the effluent concentration constraint. The inclusion of variability and uncertainty can also produce a shift in the locations of the least-cost configuration regions, which are dependent on the expected influent water quality and the magnitude of variability and uncertainty. The additional information provided by incorporating the variable and uncertain parameters illustrates that parameter distributions related to the primary removal mechanism are critical, and that contact and direct filtration are more sensitive to variability and uncertainty than conventional filtration.
publisherAmerican Society of Civil Engineers
titleDrinking Water Treatment Plant Design Incorporating Variability and Uncertainty
typeJournal Paper
journal volume133
journal issue3
journal titleJournal of Environmental Engineering
identifier doi10.1061/(ASCE)0733-9372(2007)133:3(303)
treeJournal of Environmental Engineering:;2007:;Volume ( 133 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record