Show simple item record

contributor authorLiang-Chuan Chen
contributor authorDuu-Jong Lee
contributor authorShan-Shan Chou
date accessioned2017-05-08T21:52:09Z
date available2017-05-08T21:52:09Z
date copyrightNovember 2006
date issued2006
identifier other%28asce%290733-9372%282006%29132%3A11%281523%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/64765
description abstractOperators at waterworks in which flat-bottom floc blanket clarifiers are used, are advised to increase coagulant dose when the turbidity of clarified water is high, to stabilize the blanket and yield quality drinking water. This work showed that, even when the raw water is sufficiently alkaline, the blanket responded anomalously to the increased dose of polyaluminum chloride (PACl), which was used herein as a coagulant. Restated, rather than being stabilized, the blanket was
publisherAmerican Society of Civil Engineers
titleCharge Reversal Effect on Blanket in Full-Scale Floc Blanket Clarifier
typeJournal Paper
journal volume132
journal issue11
journal titleJournal of Environmental Engineering
identifier doi10.1061/(ASCE)0733-9372(2006)132:11(1523)
treeJournal of Environmental Engineering:;2006:;Volume ( 132 ):;issue: 011