Show simple item record

contributor authorMarwa M. Hassan
contributor authorIbrahim Odeh
contributor authorKhaled El-Rayes
date accessioned2017-05-08T21:39:14Z
date available2017-05-08T21:39:14Z
date copyrightJanuary 2011
date issued2011
identifier other%28asce%29co%2E1943-7862%2E0000260.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/58406
description abstractWith the increasing needs to adopt nighttime construction strategies in order to avoid disruption of traffic flow, state agencies are currently experimenting with a new class of light towers known as balloon lights. Compared to regular lighting tower, balloon lights have been reported to reduce glare significantly and to provide more uniform lighting conditions at the site. The objective of this study was to measure light and glare characteristics of two balloon lighting systems in the field. Glare and lighting characteristics of this new class of light towers were compared to a conventional lighting system. For this purpose, field measurements were made of the pavement luminance and the horizontal and vertical illuminances on a predefined experimental grid. Results of this study indicated that while being comparable in terms of wattage and luminous flux, the tested balloon light systems differed in terms of light and glare characteristics. In addition, while conventional light tower provided greater illuminance at the light source than balloon lights, the disability glare was greater for conventional light tower than balloon lights when mounted at the same height. Results of this study revealed that optimum conditions should be sought in the work zone, through which adequate lighting conditions are provided for workers while disability glare is kept below a safe threshold for drive-by motorists. Plotting the maximum veiling luminance ratio (disability glare) against the workable distance provides a simple approach to consider the two factors concurrently in the design of work zone lighting.
publisherAmerican Society of Civil Engineers
titleNew Approach to Compare Glare and Light Characteristics of Conventional and Balloon Lighting Systems
typeJournal Paper
journal volume137
journal issue1
journal titleJournal of Construction Engineering and Management
identifier doi10.1061/(ASCE)CO.1943-7862.0000253
treeJournal of Construction Engineering and Management:;2011:;Volume ( 137 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record