Show simple item record

contributor authorJohn W. van de Lindt
contributor authorRakesh Gupta
contributor authorShiling Pei
contributor authorKazuki Tachibana
contributor authorYasuhiro Araki
contributor authorDouglas Rammer
contributor authorHiroshi Isoda
date accessioned2017-05-08T21:37:29Z
date available2017-05-08T21:37:29Z
date copyrightFebruary 2012
date issued2012
identifier other%28asce%29cf%2E1943-5509%2E0000206.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57792
description abstractIn the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world’s largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building’s seismic performance in terms of response kinematics and observed damage. This paper presents the results of detailed damage inspections following each test in a series of five shake table tests, and explains their qualitative synthesis to provide design method validation. The seismic test program had two phases. Phase I was the testing of a seven-story mixed-use building with the first story consisting of a steel special moment frame (SMF) and stories 2–7 made of light-frame wood. In Phase II, the SMF was heavily braced such that it effectively became an extension of the shake table and testing was conducted on only stories 2–7, making the building a six-story light-frame multifamily residential building instead of a mixed-use building. All earthquake motions were scalings of the 1994 Northridge earthquake at the Canoga Park recording station with seismic intensities ranging from peak ground accelerations of 0.22 to 0.88 g. The building performed quite well during all earthquakes with damage only to the gypsum wall board (drywall), no sill plate splitting, no nails withdrawing or pulling through the sheathing, no edge tearing of the sheathing, no visible stud splitting around tie-down rods, and reasonable floor accelerations. On the basis of damage inspection, it was concluded that it is possible to design this type of building and keep the damage to a manageable level during major earthquakes by utilizing the new design approach.
publisherAmerican Society of Civil Engineers
titleDamage Assessment of a Full-Scale Six-Story Wood-Frame Building Following Triaxial Shake Table Tests
typeJournal Paper
journal volume26
journal issue1
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)CF.1943-5509.0000202
treeJournal of Performance of Constructed Facilities:;2012:;Volume ( 026 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record