Show simple item record

contributor authorYu Bai
contributor authorThomas Keller
date accessioned2017-05-08T21:36:21Z
date available2017-05-08T21:36:21Z
date copyrightJune 2011
date issued2011
identifier other%28asce%29cc%2E1943-5614%2E0000194.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57316
description abstractThe postfire mechanical performances of water-cooled full-scale GFRP cellular columns subjected to axial compression were evaluated after exposure to an ISO-834 fire from one side for periods of 60 and 120 mins. The elastic modulus and postfire buckling loads exhibited significant recovery after cooling because of the partial reversibility of glass transition. Existing methods to predict ultimate loads based on experimental buckling curves have proved inaccurate. Ultimate loads were accurately predicted, however, based on a shear failure criterion and by taking large initial imperfections caused by fire damage into account. Recently developed models to predict time- and temperature-dependent material and postfire properties showed good agreement with the experimental results and were thus further validated.
publisherAmerican Society of Civil Engineers
titleFire Performance of Water-Cooled GFRP Columns. II: Postfire Investigation
typeJournal Paper
journal volume15
journal issue3
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0000191
treeJournal of Composites for Construction:;2011:;Volume ( 015 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record