Show simple item record

contributor authorAntonio De Luca
contributor authorFabio Nardone
contributor authorFabio Matta
contributor authorAntonio Nanni
contributor authorGian Piero Lignola
contributor authorAndrea Prota
date accessioned2017-05-08T21:36:15Z
date available2017-05-08T21:36:15Z
date copyrightFebruary 2011
date issued2011
identifier other%28asce%29cc%2E1943-5614%2E0000155.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57272
description abstractThe external confinement of RC columns by means of externally bonded fiber-reinforced polymer (FRP) laminates is a well established technique for strengthening and retrofitting purposes. This paper presents a pilot research that includes laboratory testing of full-scale square and rectangular RC columns externally confined with glass and basalt-glass FRP laminates and subjected to pure axial load. Specimens that are representative of full-scale building columns were designed according to a dated American Concrete Institute (ACI) 318 code (i.e., prior to 1970) for gravity loads only. The study was conducted to investigate how the external confinement affects peak axial strength and deformation of a prismatic RC column. The results showed that the FRP confinement increases concrete axial strength, but it is more effective in enhancing concrete strain capacity. The discussion of the results includes a comparison with the values obtained using existing constitutive models.
publisherAmerican Society of Civil Engineers
titleStructural Evaluation of Full-Scale FRP-Confined Reinforced Concrete Columns
typeJournal Paper
journal volume15
journal issue1
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0000152
treeJournal of Composites for Construction:;2011:;Volume ( 015 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record