Show simple item record

contributor authorHåkan Nordin
contributor authorBjörn Täljsten
date accessioned2017-05-08T21:30:51Z
date available2017-05-08T21:30:51Z
date copyrightFebruary 2006
date issued2006
identifier other%28asce%291090-0268%282006%2910%3A1%2860%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54352
description abstractRetrofitting concrete structures with fiber reinforced polymer (FRP) has today grown to be a widely used method throughout most parts of the world. The main reason for this is that it is possible to obtain a good strengthening effect with a relatively small work effort. It is also possible to carry out strengthening work without changing the appearance or dimensions of the structure. Nevertheless, when strengthening a structure with external FRP, it is often not possible to make full use of the FRP. The reason for this depends mainly on the fact that a strain distribution exists over the section due to dead load or other loads that cannot be removed during strengthening. This implies that steel yielding in the reinforcement may already be occurring in the service limit state or that compressive failure in the concrete is occurring. By prestressing, a higher utilization of the FRP material is made possible. It is extremely important to ensure that, if external prestressing is used, the force is properly transferred to the structure. Most of the research conducted with prestressing carbon fiber reinforced polymer (CFRP) for strengthening has been on surface bonded laminates. However, this paper presents research on prestressed CFRP quadratic rods bonded in sawed grooves in the concrete cover. This method has proven to be an advantageous means of bonding CFRP to concrete, and in comparison to surface bonded laminates, the shear and normal stress between the CFRP and the concrete are more efficiently transferred to the structure. In the presented test, no mechanical device has been used to maintain the prestress during testing, which means that the adhesive must transfer all shear stresses to the concrete. Fifteen beams with a length of
publisherAmerican Society of Civil Engineers
titleConcrete Beams Strengthened with Prestressed Near Surface Mounted CFRP
typeJournal Paper
journal volume10
journal issue1
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)1090-0268(2006)10:1(60)
treeJournal of Composites for Construction:;2006:;Volume ( 010 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record