Show simple item record

contributor authorThomas Sputo
contributor authorKevin Beery
date accessioned2017-05-08T21:22:17Z
date available2017-05-08T21:22:17Z
date copyrightSeptember 2008
date issued2008
identifier other%28asce%291076-0431%282008%2914%3A3%2885%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48800
description abstractThe problem of determining adequate bracing for multiple studs in a wall with similar imperfections is addressed. Previous studies have determined the necessary brace strength and stiffness required to adequately brace a single axially loaded cold-formed steel stud and this information has been incorporated into design standards. Using elastic nonlinear frame analysis software, the required bracing strength and stiffness demand for a single compression member that was derived by Winter and recommended by previous studies was replicated. The model was then expanded to include walls with up to 30 studs, braced at both the midpoint and third point. For these models the required brace stiffness and the resulting brace forces were recorded and compared to the requirements for a single stud. Analysis of the data indicates that the required brace strength accumulates directly as to the number of braced studs. The required brace stiffness for bracing multiple studs may be determined through the use of a simple second-order equation.
publisherAmerican Society of Civil Engineers
titleBracing Demand in Axially Loaded Cold-Formed Steel Stud Walls
typeJournal Paper
journal volume14
journal issue3
journal titleJournal of Architectural Engineering
identifier doi10.1061/(ASCE)1076-0431(2008)14:3(85)
treeJournal of Architectural Engineering:;2008:;Volume ( 014 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record