Show simple item record

contributor authorW. K. Chow
date accessioned2017-05-08T21:21:49Z
date available2017-05-08T21:21:49Z
date copyrightJune 1997
date issued1997
identifier other%28asce%291076-0431%281997%293%3A2%2889%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48514
description abstractThe smoke aspects in the escape routes for a three-level apartment are studied using the fire zone model CFAST 2.0. The smoke temperature and smoke layer interface heights in the corridors and staircases are analyzed. Performance of smoke control systems including ceiling vents (vent size of 1–4 m
publisherAmerican Society of Civil Engineers
titleStudy on Smoke Movement and Control for Fires in Apartments
typeJournal Paper
journal volume3
journal issue2
journal titleJournal of Architectural Engineering
identifier doi10.1061/(ASCE)1076-0431(1997)3:2(89)
treeJournal of Architectural Engineering:;1997:;Volume ( 003 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record