Show simple item record

contributor authorXiaosheng Wei
contributor authorZongjin Li
date accessioned2017-05-08T21:17:58Z
date available2017-05-08T21:17:58Z
date copyrightFebruary 2006
date issued2006
identifier other%28asce%290899-1561%282006%2918%3A1%2899%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/46111
description abstractAn electrical measurement technique was used to measure the electrical resistivity of cement paste having varying water/cement (w/c) ratios, and consequently the paste properties and characteristics were analyzed. The different hydration periods were identified from the electrical resistivity curve and the differential electrical resistivity curve. The setting time for the samples is reached before the first peak of the differential electrical resistivity curve, and this can provide a new method to determine setting time by using electrical resistivity measurements. The relation between w/c ratio and bulk resistivity at a fixed curing time follows a power law, so electrical resistivity can be used for determination of the w/c ratio in fresh and hardened cement pastes after calibration.
publisherAmerican Society of Civil Engineers
titleEarly Hydration Process of Portland Cement Paste by Electrical Measurement
typeJournal Paper
journal volume18
journal issue1
journal titleJournal of Materials in Civil Engineering
identifier doi10.1061/(ASCE)0899-1561(2006)18:1(99)
treeJournal of Materials in Civil Engineering:;2006:;Volume ( 018 ):;issue: 001