Show simple item record

contributor authorG. Sarangapani
contributor authorB. V. Venkatarama Reddy
contributor authorK. S. Jagadish
date accessioned2017-05-08T21:17:49Z
date available2017-05-08T21:17:49Z
date copyrightApril 2005
date issued2005
identifier other%28asce%290899-1561%282005%2917%3A2%28229%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/46024
description abstractThis paper focuses on some issues pertaining to brick-mortar bond and masonry compressive strength. Failure theories for masonry under compression make the assumption that the bond between brick and mortar remains intact at the time of failure of the brick or mortar. The influence of bond strength on masonry compressive strength is not fully accounted for in these failure theories. In this investigation, the influence of bond strength on masonry compressive strength has been examined through an experimental program using local bricks and mortars. Masonry prism compressive strength has been determined when the brick-mortar bond strength is varied over a wide range without altering the strength and deformation characteristics of the brick and mortar. Brick-mortar bond strength has been determined through flexure bond strength and shear bond strength tests. A relationship between the masonry prism compressive strength and bond strength has been obtained. The results clearly indicate that an increase in bond strength, while keeping the mortar strength constant, leads to an increase in the compressive strength of masonry.
publisherAmerican Society of Civil Engineers
titleBrick-Mortar Bond and Masonry Compressive Strength
typeJournal Paper
journal volume17
journal issue2
journal titleJournal of Materials in Civil Engineering
identifier doi10.1061/(ASCE)0899-1561(2005)17:2(229)
treeJournal of Materials in Civil Engineering:;2005:;Volume ( 017 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record