description abstractThis article discusses the use of nondestructive and laboratory testing techniques and load testing in evaluation of fire damage to precast prestressed concrete members in a parking structure. The in situ evaluation phase consisted of nondestructive testing of concrete using ultrasonic pulse velocity and radiographic exposures to locate tendons prior to the removal of cores. Flexural strength of concrete and dynamic Young’s modulus of elasticity and air permeability index of