contributor authorJames C. Anderson
contributor authorRoy G. Johnston
date accessioned2017-05-08T21:14:50Z
date available2017-05-08T21:14:50Z
date copyrightNovember 1998
date issued1998
identifier other%28asce%290887-3828%281998%2912%3A4%28186%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/44166
description abstractA two-story, steel moment frame building that was severely damaged during the Northridge earthquake (1994) is studied in detail. Immediately following the earthquake, the building was judged unsafe for occupancy due to a residual displacement of 7.6 cm (3 in.) in the first story. Opening of the exterior facade revealed severe cracking in the moment connections. All connections contained cracks that started in the weld at the bottom flange of the beam and propagated across the column flange and into the column panel zone. Four welded, beam-to-column, moment connections were taken from the building for additional cyclic testing under controlled conditions in the laboratory to evaluate their residual strength and deformation capacity. Results indicate that the badly damaged specimens still have significant residual strength and deformation capacity. All damaged specimens were tested to 3% rotation.
publisherAmerican Society of Civil Engineers
titlePerformance of Steel Frame Building which Experienced Intense Ground Motion
typeJournal Paper
journal volume12
journal issue4
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)0887-3828(1998)12:4(186)
treeJournal of Performance of Constructed Facilities:;1998:;Volume ( 012 ):;issue: 004
contenttypeFulltext