Show simple item record

contributor authorDuc Q. Tran
contributor authorSuman Neupane
contributor authorChris P. Pantelides
date accessioned2026-02-16T21:30:49Z
date available2026-02-16T21:30:49Z
date copyright2025/04/01
date issued2025
identifier otherJCCOF2.CCENG-5031.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4309314
description abstractA numerical model simulating the seismic behavior of precast concrete columns confined with a glass fiber–reinforced polymer (GFRP) spiral reinforced with longitudinal steel or a combination of steel and GFRP bars was developed. Four column specimens confined with GFRP spirals longitudinally reinforced with either only steel longitudinal bars (all-steel) or a combination of steel and GFRP longitudinal bars (hybrid) were tested under cyclic loads. Two columns, one hybrid and one all-steel, were post-tensioned using high-strength steel bars. For the post-tensioned columns, carbon fiber–reinforced polymer (CFRP) jackets were applied externally at the column end. The columns were connected to the footings using grouted duct connections. A computational model using OpenSees is presented to analyze the cyclic response of the precast reinforced/post-tensioned concrete columns with grouted ducts reinforced with a hybrid arrangement of steel and GFRP bars. The numerical model incorporates plastic hinge length, buckling, bond slip, and low cycle fatigue of intentionally debonded steel reinforcing bars. Material models for confined concrete by two layers of GFRP internal spirals and CFRP external jackets, reinforcing steel bars, GFRP bars, and post-tensioned high strength steel bars proved their effectiveness in simulating the experiments. Satisfactory agreement between the model and experiments was observed. The numerical model predicted bar fracture during the same drift ratio as the experiments. The cumulative hysteretic energy of the numerical models deviated from the experiments by <6.0%. The difference in peak post-tensioning force between the numerical model and the experiments was <5.0%.
publisherAmerican Society of Civil Engineers
titleSeismic Analysis of Precast and Post-Tensioned Column-to-Footing Connections with Steel–GFRP Bars and GFRP Spirals
typeJournal Article
journal volume29
journal issue2
journal titleJournal of Composites for Construction
identifier doi10.1061/JCCOF2.CCENG-5031
journal fristpage04025001-1
journal lastpage04025001-17
page17
treeJournal of Composites for Construction:;2025:;Volume ( 029 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record