Show simple item record

contributor authorXiaohong Gui
contributor authorHaiteng Xue
contributor authorZhengyu Hu
contributor authorJunwei Zhu
contributor authorShiqing Xing
date accessioned2025-04-20T10:06:21Z
date available2025-04-20T10:06:21Z
date copyright12/24/2024 12:00:00 AM
date issued2025
identifier otherJPSEA2.PSENG-1501.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303996
description abstractTo investigate cable cabin fire characteristics, a 1∶1 full-scale model was built according to the actual situation of cable cabins in a comprehensive pipe gallery in a city to simulate cable cabin fires. Through the ventilation mode of the cable compartment in case of fire, the influence of different ventilation rates on the cable compartment fire under the conditions of closing the cable compartment ventilation system, natural air intake + mechanical exhaust ventilation mode, and mechanical air intake + mechanical exhaust ventilation mode was explored. The research demonstrates that the progression of fire within the cable compartment situated in the comprehensive pipe gallery follows a five-stage sequence: smoldering, incipient, developing, violent, and attenuation. Without a fire extinguishing system in place, the oxygen within the cable compartment can sustain the fire for approximately 450 s. Elevated CO2 concentrations are detected at the center, top, and ends of the cable bin, while the lowest CO2 concentration is observed at the bottom of the cable bin. Initiating the natural air intake with a mechanical exhaust ventilation system and maintaining a low ventilation rate of approximately 2  times/h is optimal for fire development and temperature dispersion. Under the mechanical air intake with mechanical exhaust ventilation mode, high ventilation rates of 8  times/h and 10  times/h significantly exacerbate the fire. The findings of this study can offer valuable guidance for the development of fire protection systems for cable cabins. This study investigates fire behavior in cable chamber scenarios under various ventilation modes, particularly focusing on the effects of natural air intake with mechanical exhaust and mechanical air intake with mechanical exhaust on fire development. The findings indicate that lower ventilation rates aid in fire control, whereas higher rates may exacerbate fire progression. These insights provide a scientific basis for designing fire suppression systems, establishing safety standards, formulating emergency response plans, and optimizing engineering designs in enclosed spaces such as cable chambers. This research contributes to enhancing the fire safety capabilities of these high-risk facilities, ensuring the safety of both personnel and equipment.
publisherAmerican Society of Civil Engineers
titleStudy on Fire Dynamics of a Cable Compartment in an Underground Comprehensive Pipe Gallery
typeJournal Article
journal volume16
journal issue2
journal titleJournal of Pipeline Systems Engineering and Practice
identifier doi10.1061/JPSEA2.PSENG-1501
journal fristpage04024077-1
journal lastpage04024077-14
page14
treeJournal of Pipeline Systems Engineering and Practice:;2025:;Volume ( 016 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record