Show simple item record

contributor authorEdoniyas Birhanu Radie
contributor authorGirum Urgessa
contributor authorTesfaye Alemu Mohammed
date accessioned2024-12-24T10:11:35Z
date available2024-12-24T10:11:35Z
date copyright11/1/2024 12:00:00 AM
date issued2024
identifier otherPPSCFX.SCENG-1475.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4298463
description abstractConcrete-filled fiber tubes (CFFT) are gaining prominence as a feasible alternative to traditional materials for a variety of structural applications. However, research on structural performance of CFFT beams is still scarce. This paper presents a finite-element (FE) analysis of CFFT beams validated by experimental results from literature. Then, a parametric study investigating structural performance of post-tensioned (PT CFFT) beams was conducted using 34 FE models using ANSYS nonlinear FE software program. The parametric study results showed that both normal-strength concrete (NSC) and high-strength concrete (HSC) filled PT CFFT exhibit identical nonlinear responses. Increasing the prestressed and non-prestressed reinforcement ratio significantly improved the overall performance of PT CFFT beams. Placing the PT tendons at the bottom of PT CFFT beams enhanced the cracking, yielding, and ultimate load-carrying capacities by 7.98%, 12.32%, and 9.03% for NSC-filled PT CFFT beams, respectively. Doubling the axial stiffness of the tube laminate structure increased the ultimate load, energy absorption capacity (EAC), pre-yielding stiffness (Kpre), and post-yielding stiffness (Kpos) by 18.5%, 12.15%, 9.21%, and 8.2%, respectively for NSC-filled PT CFFT beams. Beams with straight PT tendons exhibited increased cracking, yielding, and ultimate load capacity by 10.85%, 14.60%, and 13.58% more than those with curved-profile tendons. The ductility of PT CFFT beams is more sensitive to the amount of prestressed reinforcement ratio and concrete strength has a minimal effect on the structural performance of PT CFFT beams.
publisherAmerican Society of Civil Engineers
titleNumerical Study of Flexural Behavior of Post-Tensioned Concrete-Filled Fiber-Reinforced Polymer Tube Beam
typeJournal Article
journal volume29
journal issue4
journal titlePractice Periodical on Structural Design and Construction
identifier doi10.1061/PPSCFX.SCENG-1475
journal fristpage04024056-1
journal lastpage04024056-16
page16
treePractice Periodical on Structural Design and Construction:;2024:;Volume ( 029 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record